Universidade de Lisboa Repositório da Universidade de Lisboa

Repositório da Universidade de Lisboa >
Faculdade de Medicina Dentária (FMD) >
FMD - Teses de Doutoramento >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10451/7348

Title: Adesão indirecta de brackets ortodônticos:estudo clínico e laboratorial
Authors: Pereira, Rui, 1958-
Advisor: Jardim, Luís, 1962-
Portugal, Jaime, 1969-
Keywords: Ortodontia
Teses de doutoramento - 2012
Issue Date: 2012
Abstract: A presente tese teve como objectivo comparar a técnica indirecta com a directa na adesão de brackets ortodônticos. Na técnica indirecta foram estudados os efeitos do material de impressão, das moldeiras de transferência e de diferentes adesivos. Foi estudado igualmente o efeito do envelhecimento, provocado pelo tempo que medeia entre a preparação dos brackets para a técnica indirecta e a sua cimentação (um dia versus 28 dias). Para tal foram desenhados dois estudos laboratoriais e um ensaio clínico. O primeiro estudo, efectuado em dentes bovinos, não revelou a existência de diferenças nos valores de adesão entre a técnica directa e a técnica indirecta. Na técnica indirecta foram avaliados; (i) dois materiais de impressão – um alginato e um poliéter, (ii) três moldeiras de transferência, (iii) três sistemas adesivos – um fotopolimerizável (Filtek Supreme XT FlowTM), um autopolimerizável (ConciseTM) e um no-mix (Sondhi Rapid SetTM). Não foram encontradas diferenças, em termos de valores de adesão, entre a utilização de impressões em alginato ou em elastómero, ou entre a utilização das diferentes moldeiras de transferência. O estudo demonstrou que os valores de adesão obtidos com a utilização do Filtek Supreme XT FlowTM foram estatisticamente superiores aos do sistema adesivo ConciseTM. O segundo estudo, executado em dentes humanos, identificou uma diminuição significativa dos valores de adesão obtidos pela técnica indirecta quando a cimentação dos brackets foi efectuada vinte e oito dias após a preparação dos brackets, com os valores de adesão significativamente inferiores aos proporcionados pela técnica directa. Neste estudo não foram encontradas diferenças significativas em termos de adesão entre a técnica directa e a técnica indirecta, quando efectuada um dia após a preparação dos brackets. O ensaio clínico não gerou evidência de diferenças entre a técnica directa e a técnica indirecta em termos de taxa de sobrevivência dos brackets.
This PhD thesis studied the differences between the direct and the indirect technique in bonding orthodontic brackets. The aim of this investigation was to examine the influence of the impression material and different transfer trays, on the adhesion provided by different adhesive systems of brackets placed by the indirect technique. This work, also aimed to study the influence of aging of the custom composite base of brackets, in the indirect technique, (one day versus 28 days) before bonding. Two experimental studies and a clinical trial were carried to achieve these goals. The first experimental study was done on deciduous bovine teeth and showed no differences in the shear bond strength (SBS) achieved with both techniques. In the indirect technique we evaluated (i) two impression materials – an alginate and a polieter – (ii) three transfer trays, (iii) three adhesive systems – a photopolymerized one (Filtek Supreme XT FlowTM), a self cure (ConciseTM) and a no mix (Sondhi Rapid SetTM). There were no differences among the use of any of the impression materials or the transfer trays. The use of Filtek Supreme XT Flow as an adhesive, showed significantly higher SBS than the use of Concise. The second study, done on human premolars, showed that the 28 days aging of the indirect custom base resulted in a significantly decrease in the SBS for all the adhesives tested and significantly inferior to the direct bonding technique. There were no differences between the direct technique and the indirect technique when the aging period was just one day. The clinical trial showed that there were no significant differences in the bond failure rates between the direct technique and the indirect technique done one day after bracket preparation.
Description: Tese de doutoramento, Medicina Dentária (Ortodontia), Universidade de Lisboa, Faculdade de Medicina Dentária, 2012
URI: http://hdl.handle.net/10451/7348
http://catalogo.ul.pt/F/?func=item-global&doc_library=ULB01&type=03&doc_number=000655131
Appears in Collections:FMD - Teses de Doutoramento

Files in This Item:

File Description SizeFormat
ulsd063613_td_Rui_Pereira.pdf3.32 MBAdobe PDFView/Open
Statistics
FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpaceOrkut
Formato BibTex mendeley Endnote Logotipo do DeGóis 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

  © Universidade de Lisboa / SIBUL
Alameda da Universidade | Cidade Universitária | 1649-004 Lisboa | Portugal
Tel. +351 217967624 | Fax +351 217933624 | repositorio@reitoria.ul.pt - Feedback - Statistics
DeGóis
  Estamos no RCAAP Governo Português separator Ministério da Educação e Ciência   Fundação para a Ciência e a Tecnologia

Financiado por:

POS_C UE